John Energy has erected and is operating the Gas De-hydration plant. GLYCOL DEHYDRATION SYSTEM is a liquid desiccant system is used for the removal of water from natural gas and natural gas liquid. It is the most common and economical means of water removal from these gases. The purpose of a glycol dehydration unit is to remove water from natural gas and natural gas liquids, when produced from a reservoir.
Plant Specifications
Plant Parameters |
Gas Dehydration Plant Odalarevu, Kakinada, Andhra Pradesh, India |
NARSAPUR Gas Dehydration Plant, Andhra Pradesh, India |
Gas handled |
HP Gas |
HP Gas |
Type of Unit |
Glycol Dehydration Unit |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Make of Plant |
Gas Technology Corporation (USA) |
Gas Technology Corporation (USA) |
Model |
Gas Technology GDU-30.0 |
Gas Technology GDU-2.5 |
Capacity |
30.0 MMSCMD |
200000 SCMD |
Pressure |
782 psig (55 kg) |
782 psig (55 kg) |
Temperature |
55 °C |
55 °C |
Pressure Drop Across GDU |
21.3 psig (1.5 kg/cm2) |
28.4 psig (2 kg/cm2) |
Capacity (Contractual Quantity) |
2500000 SCMD |
200000 SCMD |
Inlet Gas Pressure |
51.5 (kg/cm2) |
57 (kg/cm2) |
Inlet Gas Temperature |
25/50 (°C) |
25/50 (°C) |
Outlet Gas Pressure |
50 kg/cm2 |
55 kg/cm2 |
Outlet Gas Temperature |
40 (°C) |
55 (°C) |
Contractual Quantity (Operating) |
2500000 SCMD |
200000 SCMD |
Plant Parameters |
MORI Gas Dehydration Plant, Andhra Pradesh, India |
PASARLAPUDI Gas Dehydration Plant, Andhra Pradesh, India |
Gas handled |
HP Gas |
HP Gas |
Type of Unit |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Make of Plant |
Gas Technology Corporation (USA) |
Gas Technology Corporation (USA) |
Model |
Gas Technology GDU-3.5 X 2 |
Gas Technology GDU-5.0 |
Capacity |
350000 SCMD X 2 |
500000 SCMD |
Pressure |
782 psig (55 kg) |
782 psig (55 kg) |
Temperature |
55 °C |
55 °C |
Pressure Drop Across GDU |
28.4 psig (2 kg/cm2) |
28.4 psig (2 kg/cm2) |
Capacity (Contractual Quantity) |
2500000 SCMD |
2500000 SCMD |
Inlet Gas Pressure |
57 (kg/cm2) |
57 (kg/cm2) |
Inlet Gas Temperature |
25/50 (°C) |
25/50 (°C) |
Outlet Gas Pressure |
55 kg/cm2 |
55 kg/cm2 |
Outlet Gas Temperature |
55 (°C) |
55 (°C) |
Contractual Quantity (Operating) |
700000 SCMD |
500000 SCMD |
Plant Parameters |
MANDAPETA Gas Dehydration Plant, Andhra Pradesh, India |
KESANAPALLI Gas Dehydration Plant, Andhra Pradesh, India |
Gas handled |
HP Gas |
HP Gas |
Type of Unit |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Make of Plant |
Gas Technology Corporation (USA) |
Gas Technology Corporation (USA) |
Model |
Gas Technology GDU-3.5 X 3 |
Gas Technology GDU-5.0 |
Capacity |
350000 SCMD X 3 |
500000 SCMD |
Pressure |
782 psig (55 kg) |
782 psig (55 kg) |
Temperature |
55 °C |
55 °C |
Pressure Drop Across GDU |
28.4 psig (2 kg/cm2) |
28.4 psig (2 kg/cm2) |
Capacity (Contractual Quantity) |
2500000 SCMD |
2500000 SCMD |
Inlet Gas Pressure |
57 (kg/cm2) |
57 (kg/cm2) |
Inlet Gas Temperature |
25/50 (°C) |
25/50 (°C) |
Outlet Gas Pressure |
55 kg/cm2 |
55 kg/cm2 |
Outlet Gas Temperature |
55 (°C) |
55 (°C) |
Contractual Quantity (Operating) |
1050000 SCMD |
500000 SCMD |
Plant Parameters |
TATIPAKA Gas Dehydration Plant, Andhra Pradesh, India |
ENDAMURU Gas Dehydration Plant, Andhra Pradesh, India |
Gas handled |
HP Gas |
HP Gas |
Type of Unit |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Glycol Dehydration & Hydrocarbon Dew Point Depresion System |
Make of Plant |
Gas Technology Corporation (USA) |
Gas Technology Corporation (USA) |
Model |
Gas Technology GDU-3.5 |
Gas Technology GDU-2.0 |
Capacity |
350000 SCMD |
200000 SCMD |
Pressure |
782 psig (55 kg) |
782 psig (55 kg) |
Temperature |
55 °C |
55 °C |
Pressure Drop Across GDU |
28.4 psig (2 kg/cm2) |
28.4 psig (2 kg/cm2) |
Capacity (Contractual Quantity) |
2500000 SCMD |
2500000 SCMD |
Inlet Gas Pressure |
57 (kg/cm2) |
57 (kg/cm2) |
Inlet Gas Temperature |
25/50 (°C) |
25/50 (°C) |
Outlet Gas Pressure |
55 kg/cm2 |
55 kg/cm2 |
Outlet Gas Temperature |
55 (°C) |
55 (°C) |
Contractual Quantity (Operating) |
350000 SCMD |
200000 SCMD |